Resin

Level 2: Supervised, scheduled sessions

Resin

Skin contact, isopropanol and UV exposure to keep under control before using the resin printer.

Created by:  Adrien Bracq

Who this module is for

Any campus user who wants to use the MakerSpace resin printer or the UV wash and cure station. Use of these machines is still marginal: this module is not open continuously, but offered through a few dedicated sessions scheduled during the year. Contact the MakerSpace manager to find out the next dates or to express your interest.

Why this level of vigilance

Unlike FDM, uncured liquid resin is an irritant, or even a skin sensitiser, and the isopropanol (IPA) used to clean the parts is flammable. Some effects are not immediate but get worse with repeated exposure: feeling nothing at the time does not mean there is no consequence later.

Identified risks

Skin contact with liquid resin (cumulative risk)

Moderate risk

Risk of irritation and, with repetition, of allergic sensitisation: the effects can get worse with repeated exposure over time, even with no visible reaction at first. Resin must never be handled with bare hands.

Inhalation of vapours

Moderate risk

During printing and cleaning, volatile compounds are given off.

Isopropanol (IPA)

High risk

Flammable and irritant, to be handled and stored with care, away from any source of heat or flame, and from incompatible products.

UV exposure

Moderate risk

Post-curing uses UV radiation, never in the open in the presence of other people.

PPE and equipment required

Nitrile gloves (disposable) Safety glasses FFP2 mask or cartridge half-mask

Nitrile gloves are mandatory for any handling of liquid resin. The mask (FFP2 or cartridge half-mask) is needed if the ventilation of the area is insufficient.

Instructions before / during use

Check that the machine is not flagged as under maintenance or out of service before using it.

Read the safety data sheet (SDS) and the hazard pictograms of the product used (resin, IPA) before any handling, especially if you change resin.

The fume hood must be running during any handling of liquid resin or isopropanol.

Never handle liquid resin without gloves.

Work with the cover closed during printing.

Clean with isopropanol in a ventilated area, away from any source of heat or flame.

Store resin and IPA away from any source of heat and from incompatible products, in a spill tray if possible.

Dispose of uncured resin and soiled wipes with the dedicated chemical waste, never with ordinary waste.

What to do in case of an incident

  The absolute rule

Whatever the incident, immediately tell the MakerSpace supervisor present: they take charge of the situation. Your safety comes first: if in doubt about an action, do not do it; raise the alarm and evacuate rather than intervene.

Skin contact: remove soiled gloves and clothing, wash thoroughly with water, seek medical advice if irritation persists.

Splash in the eye: rinse thoroughly with clean water for at least 15 minutes; always seek medical advice.

Need help?